CAT: BFP/VCAR
3.3 Corsa
(Stroke)
2.3 Corsa
2.3 Corsa
(Stroke)
(Stroke)
max7 Nm
max7 Nm
max7 Nm
38.2 max
29.5
27
Ø10
8
2.3 Corsa
(Stroke)
3/4 - 16 UNF
2
1
93.6 (NA)
38.6
(*)
Ø12.7
Ø20
Ø20.3
Ø21
Ø10
Ø10
Ø10
2.5
27
30
66.6 (NA)
59 (NC)
86 (NC)
P4
E9
P3
42
20.5
19
24
Emergenza (NA)
Emergency (NA)
(*) 13.3 (NA)
13 (NC)
CRB04 / CRP04
1
2
2
1
IE/CRP04/006/2015 SHEET: 1/2
8
Ø 12.7
Ø 15.87
1
2
2
1
PILOTED OPERATED SOLENOID VALVE
FEATURES
HYDRAULIC SYMBOLS
Max. pressure 300 bar
Max. Flow 40 l/min
Max. Leakage (0 ÷ 10 drops/min) 0 ÷ 0.5 cm
3
/min
Max. excitation frequency 2 Hz
Duty cycle 100% ED
Hydraulic fluids DIN 51524 Mineral oils
Fluid viscosity 10 ÷ 500 mm²/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamin. level class with filter ISO 4406:1999 - class 19/17/14
Cartridge filter 280µm
Type of protection
(in relation to the connection used)
IP65
Weight (with coil) 0.27 kg
Cartridge tightening torque 25 ÷ 30 Nm
Coil ring nut tightening torque
Emergency tightening torque
7 Nm
Cavity standard “A”
(3/4 - 16 UNF)
CD018006
(See section 15)
Cavity standard “A”
+ seat VSCOA**01
CD018009
(See section 15)
Cavity with reduction “B”
(3/4 - 16 UNF)
CD018012
(See section 15)
CRP - Normally open CRP - Normally closed
CRP 04 18..
Cavity type “A”
Emergency (NC)
Variants (NA)
SOLENOID VALVES - 2-WAY
Connector to be ordered separately, see sect. 18
Reduction for cavity type “B”
V89B30000 Spare code
The pilot-operated electric 2-way 2-position directional valve is controlled
electrically.
The tapered poppet is in tempered and ground steel.
Available in normally open (NA) or normally closed (NC) versions.
00012023
Spare seals kit
Removable cup
CRB - Normally open CRB - Normally closed
Valve
Free
passage
Coil Type
CRP..NA
2 → 1 DE-ENERGISED
Unidirectional
CRP..NC
2 → 1 ENERGISED
1 → 2 DE-ENERGISED
CRB..NA
1 → 2
DE-ENERGISED
Bidirectional
2 → 1
CRB..NC
1 → 2
ENERGISED / DE-ENERGISED
2 → 1 ENERGISED
Normally closed valves can work with DC or AC coils.
Normally open valves work with DC coils whereas RAC coils with a connector
and incorporated rectifier must be used for AC applications.
The NC valve sleeve is in galvanised steel and the NA valve sleeve with nikel
coated.
Page: 70